Vacuum fixture discussion
Assume M10 × 1.5, F = 1 kN and K = 0.20. T = 2.00 N·m and nominal stress ≈17.2 MPa. For a 30 mm grip, 1400°C and assumed average CTEs 1/4.5, free mismatch is 144.9 µm.
Next: verify actual CTE, head bearing, matched-thread strength and torque–tension scatter. This is not an installation setting.